AGILE Series

The Agile Series of inverters by Bonfiglioli sets new standards in technology for a broad range of users. Agile inverters are particularly suited for the food & beverage, textile, wood, packaging and ceramic industries, where they can be used in a variety of medium complexity automation processes.

Specifications


Degree of protection
IP20 (EN 60529)

Rated speed
0 ... 599 Hz

Certifications
UL508c
STO (EN13849 / EN 61508)

Conformity
CE
EN61800

Specifications

  • Main options
    • Different Field bus options like CANopen, PROFIBUS, Modbus
    • Optional accessories like brake resistor, mains chokes, mains filters
    • Optional Connection set for connection to PC


    Optional field bus communication:
    • CM-CAN: CANopen
    • CM-PDP-V1: PROFIBUS
    • CM232: Modbus ASCII & Modbus RTU for point-to-point connection
    • CM485: Modbus ASCII & Modbus RTU via RS485 connection
    • CM-DeviceNet: DeviceNet
    • CM-EtherCAT®: EtherCAT®
    • CM-PROFINET: PROFINET
    • CM-Ethernet/IP: Ethernet/IP with one usable port as end-of-line device
    • CM-Ethernet/IP-2P: Ethernet/IP with two usable ports (daisy chaining is possible)
    • CM-Modbus/TCP: Modbus/TCP with one usable port as end-of-line device
    • CM-Modbus/TCP-2P: Modbus/TCP with two usable ports (daisy chaining is possible)
    • Ethernet VABus/TCP: VABus/TCP: with one usable port as end-of-line device
    • Ethernet VABus/TCP-2P: VABus/TCP: with two usable ports (daisy chaining is possible)

    Optional interface for communication to PC
    • ASK-USB: Communication to PC via optional communication cable

    Optional PC software
    • VPlus for Windows operating system with motor setup, terminal monitor
    • Actual value window, scope function, parameter storage

    Accessories:
    • Brake resistors Type BR: The brake resistors offer an inexpensive solution to dissipate generator power that occurs at deceleration. A thermal sensor for the brake resistor protects the resistor from overheating.
    • Power choke type LCVS & LCVT: Power choke types LCVS (for single-phase power installation) and LCVT (for three-phase power installation) increase the overvoltage protection of the inverter and increase the system's EMC.
    • Power filters type FTV: Depending on the application boundaries, certain EMC levels must be achieved. The power filters are a component to improve EMC behavior in a machine installation.
  • Power supply & Power range
    Power range (AGL402)
    0.25 - 11 kW / three-phase 320 V... 530 V / 50 - 60 Hz (± 10%)

    Power range (AGL202)
    0.12 - 3 kW / single-phase 200 V... 240 V / 50 - 60 Hz (± 10%)
    0.25 - 7.5 kW / three-phase 200 V ... 240 V / 50 - 60 Hz (± 10%)
  • Hardware features
    • Integrated Keypad
    • Integrated brake chopper
    • Integrated Safe Torque Off function
    • DC link connection
    • 6 digital inputs, 2 multifunction A/D inputs
    • 1 digital output, 1 multifunction I/O
    • 1 relay output, 1 multifunction A/D/Pulse output
    • Signal supply outputs: +24 V DC, + 10 V DC
    +24 V DC input for electronic power supply
    • Serial interfaces: RS-232, RS-485 including Modbus support
    system bus
  • Software features
    • Preset values for Bonfiglioli motors to decrease commissioning times
    • Flexible assignment of digital inputs and outputs
    • Energy Saving function
    • Ready to use application macros
    • Motor chopper function to increase braking power without brake resistors
    • Power failure regulation
    • Fault history
    • Motor and inverter state memory
    • Integrated PLC function with graphic development environment
  • Power range
    • AGL202: 0.12 - 3 kW / single-phase 200 V... 240 V / 50 - 60 Hz (± 10%) 0.25 - 7.5 kW / three-phase 200 V ...240 V / 50 - 60 Hz (± 10%)
    • AGL402: 0.25 - 11 kW / three-phase 320 V... 530 V / 50 - 60 Hz (± 10%)
  • Mounting options
    • Cabinet mounting for all sizes
    • Optional feed-through mounting
    • Optional DIN rail mounting frame
  • Motors
    • Motor compatibility
    • Two types of motors:
    • Asynchronous AC motors
    • Permanent magnet synchronous (brushless) motors
  • Motor options
    Motor Control(open loop):
    • Asynchronous AC motors
    • Permanent magnet synchronous (brushless) motors

Types & Powers

  • Types & powers (AGL402)
    Type kW (three-phase)
    AGL402-02 1 0.25
    AGL402-03 1 0.37
    AGL402-05 1 0.55
  • Types & powers (AGL402)
    Type kW (three-phase)
    AGL402-07 1 0.75
    AGL402-09 1 1.1
    AGL402-11 1 1.5
    AGL402-13 1 2.2
    AGL402-15 2 3.0
    AGL402-18 2 4.0
    AGL402-19 2 5.5
    AGL402-21 2 7.5
    AGL402-19 3 5.5
    AGL402-21 3 7.5
    AGL402-22 3 9.2
    AGL402-23 3 11
  • Types & powers (AGL202)
    Type kW (three-phase)
    AGL202-02 1 0.25
    AGL202-03 1 0.37
    AGL202-05 1 0.55
    AGL202-07 1 0.75
    AGL202-09 1 1.1
    AGL202-11 1 1.5
    AGL202-13 1 2.2
    AGL202-15 2 3.0
    AGL202-18 2 4.0
    AGL202-19 3 5.5
    AGL202-21 3 7.5
  • Types & powers (AGL202)
    Type kW (single-phase)
    AGL202-02 1 0.12
    AGL202-03 1 0.18
    AGL202-05 1 0.25
    AGL202-07 1 0.37
    AGL202-09 1 0.55
    AGL202-11 1 0.75
    AGL202-13 1 1.1
    AGL202-15 2 1.5
    AGL202-18 2 2.2
    AGL202-19 3 3
    AGL202-21 3 3
Related
Applications

Downloads

Product Catalogue –Servo-Drives- AGILE
Catalogues

Product Range I&A
Catalogues

Product Range Catalogue - Wind Industry
Catalogues

AGL Quick Start Guide
Quick Start Guide & Technical Data

Energy Efficiency AGL
Quick Start Guide & Technical Data

AGL Operating Instructions
Operating instructions

AGL Application manual Functional Safety
Applications Manuals

ACU ANG AGL Application Manual VPLC
Applications Manuals

AGL CM-EtherCAT
Communication modules

AGL CANopen
Communication modules

AGL CM-Modbus/TCP
Communication modules

AGL Modbus
Communication modules

AGL CM-PDP-V1
Communication modules

AGL CM-PROFINET
Communication modules

AGL Systembus
Communication modules

AGL CM-VABus/TCP
Communication modules

AGL VABus
Communication modules

AGL_Fieldbus_Device_Description
Other files

Vplus 8.0.8.7
Category Software

Download technical documentation

Register now to download the following documents


After having read the privacy disclosure:
By marking the relevant box below, I hereby authorise the company to process my contact data (information on my name, place and date of birth, tax code, address, telephone number, mobile telephone number, e-mail address) for marketing and advertising communication purposes, on promotional sales initiatives, trade fairs and events, receipt of newsletters, carried out using automated contact means (e-mail) and traditional contact means (for example, telephone call with an operator) or for market research and statistical surveys.

I may revoke my declaration of consent at any time to the company for future marketing communications by writing to corporatemkt@bonfiglioli.com

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.