DGM

Typology ELECTRIC

Decentralized inverter


Download documents

DGM

From the Bonfiglioli experience comes DGM, the new range of decentralized inverters for the control of asynchronous motors. DGM is perfect for the pump, ventilation and process industries thanks to the PID control, the high number of on-board I / O (digital and analog) and the integrated Soft Plc as standard for stand-alone applications. DGM can be supplied combined with a gearmotor or separately, for wall or on-board motor mounting. When the inverter is supplied with the gearmotor, mechanical assembly, wiring and basic programming are performed by Bonfiglioli, thus reducing installation times, limiting the risk of errors. Design and installation are faster than inverters installed in classic centralized switchboards.

key features

Specifications


Degree of protection
IP65

Specifications

• Application switchboard volume and cooling system reduction
• Streamlined and simpler plant design.
• Plant extensibility not affected by switchboard capacity.
• No expensive shielded power cables required (otherwise necessary to meet the EMC standards).
• Possibility of remote control thanks to the wide availability of digital and analog inputs and outputs and available field buses.
CONTROL
• Sensorless Vector Control.
• PID operation with automatic speed control.
• Automatic starting torque optimization
• Configurable operation with typical quadratic curve
• Motor-potentiometer function
• Configurable quick restart

SAFETY AND PROTECTION
• STO operating safety
• Motor protection I2t function
• Locked shaft control
• Start error assessment
• Motor current limitation based on the settings
• Embedded EMC filter in all versions

FIELD BUS
• Fieldbus option
• Automatic scrolling compensation
• Brake Chopper Option
• Brake Rectifier module Option

PROGRAMMING
• Cover embedded MMI option
• Cover embedded Foil Keypad option
• Wide range of configuration options, also thanks to the embedded PLC
DGM1
Single-phase version with a wide range of configuration options.
• 0.37 … 1.1 kW
DGM3
As for DGM1,
but in the three-phase version
• 0.55 … 22.0 kW

Types & Powers

Series - Frame kW
DGM1
DGM1 - A 0.37
DGM1 - A 0.55
DGM1 - A 0.75
DGM1 - A 1.1
DGM3
DGM3 - A 0.55
DGM3 - A 0.75
DGM3 - A 1.1
DGM3 - A 1.5
DGM3 - B 2.2
DGM3 - B 3.0
DGM3 - B 4.0
DGM3 - C 5.5
DGM3 - C 7.5
DGM3 - D 11.0
DGM3 - D 15.0
DGM3 - D 18.5
DGM3 - D 22.0

Downloads

Use arrow keys to navigate options

Catalogues
Product catalogue - DGM series

Catalogues
Product Range - I&A

Operating instructions
DGM User Manual

Operating instructions
DGM Profinet Communication Manual

Operating instructions
Man machine interface - Technical manual

Category Software
VPlus Dec 3.60

Products and solutions request
Use arrow keys to navigate options
Use arrow keys to navigate options
Use arrow keys to navigate options
Use arrow keys to navigate options
Use arrow keys to navigate options

After having read the privacy disclosure:
By marking the relevant box below, I hereby authorise the company to process my contact data (information on my name, place and date of birth, tax code, address, telephone number, mobile telephone number, e-mail address) for marketing and advertising communication purposes, on promotional sales initiatives, trade fairs and events, receipt of newsletters, carried out using automated contact means (e-mail) and traditional contact means (for example, telephone call with an operator) or for market research and statistical surveys.

I may revoke my declaration of consent at any time to the Company for future marketing communications by filling this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.